[{"command":"insert","method":null,"selector":".course-modal-ajax-placeholder-966157","data":"\u003Cdiv class=\u0022container content-rte\u0022\u003E\n  \u003Cdiv class=\u0022row\u0022\u003E\n    \u003Cdiv class=\u0022box col-md-6 bg-primary text-white\u0022\u003E\n      \u003Ch2 class=\u0022h1 text-left\u0022\u003E  Stabilit\u00e9, perturbations et protection des r\u00e9seaux \u00e9lectriques\n\u003C\/h2\u003E\n                  \u003Cdiv class=\u0022field-spacing\u0022\u003E\n        \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EECTS :\n          3\n        \u003C\/div\u003E\n      \u003C\/div\u003E\n                  \u003Cdiv class=\u0022field-spacing\u0022\u003E\n        \u003Cdiv class=\u0022field__label h3 dash\u0022\u003ESemester:\n          Semestre 1\n        \u003C\/div\u003E\n      \u003C\/div\u003E\n            \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003ED\u00e9tail du volume horaire\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                          \u003Cspan class=\u0022field__label h4 mt-5 \u0022\u003ELecture:\u003C\/span\u003E\n                                      \u003Cspan\u003E18\u003C\/span\u003E\n                      \u003C\/div\u003E\n                                              \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                          \u003Cspan class=\u0022field__label h4 mt-5 \u0022\u003EDirected study:\u003C\/span\u003E\n                                      \u003Cspan\u003E3\u003C\/span\u003E\n                      \u003C\/div\u003E\n                                                            \u003C\/div\u003E\n        \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003ELangue d\u0026#039;enseignement\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003EFran\u00e7ais\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n        \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EEnseignement \u00e0 distance\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003Enon\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n      \u003C\/div\u003E\n    \u003Cdiv class=\u0022box col-md-6\u0022\u003E\n            \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EPr\u00e9requis\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003E\u003Cp\u003EConnaissance du fonctionnement et du r\u00e9glage des r\u00e9seaux \u00e9lectriques, mod\u00e9lisation de la machine synchrone en r\u00e9gime transitoire.\u003C\/p\u003E\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n        \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EProgramme \/ plan \/ contenus\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003E\u003Cul\u003E\n\u003Cli\u003EStabilit\u00e9 transitoire des r\u00e9seaux \u00e9lectriques.\u003C\/li\u003E\n\u003Cli\u003EBureau d\u2019\u00e9tude sur la stabilit\u00e9 transitoire\u003C\/li\u003E\n\u003Cli\u003EG\u00e9n\u00e9ralit\u00e9s sur les perturbations, et la protection\u003C\/li\u003E\n\u003Cli\u003ECalcul du courant de d\u00e9faut\u0026nbsp;\u003C\/li\u003E\n\u003Cli\u003E\u00c9tude de cas\u0026nbsp;\u003C\/li\u003E\n\u003Cli\u003EImpact des EnRs sur les r\u00e9seaux et leur protection.\u003C\/li\u003E\n\u003C\/ul\u003E\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n        \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EObjectifs d\u0026#039;apprentissage\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003E\u003Cp\u003Ecomprendre les notions de stabilit\u00e9 transitoire des syst\u00e8mes \u00e9lectriques, la mod\u00e9lisation pour les \u00e9tudes de stabilit\u00e9 transitoire, la simulation d\u0027un groupe connect\u00e9 au r\u00e9seau\u003Cbr\u003E\nconnaitre les perturbations affectant les r\u00e9seaux \u00e9lectriques, l\u0027impact de d\u00e9fauts \u0026nbsp;sur le r\u00e9seau; savoir calculer les courants de d\u00e9fauts, simuler un r\u00e9seau en d\u00e9faut, comprendre le r\u00f4le d\u0027un syst\u00e8me de protection et les strat\u00e9gies de protection.\u003C\/p\u003E\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n        \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EOrganisation g\u00e9n\u00e9rale et modalit\u00e9s p\u00e9dagogiques\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003E\u003Cp\u003ECe module comporte 7 s\u00e9ances de 3h face \u00e0 face (6 cours et 1 TD). En plus, les \u00e9tudiants auront des devoirs \u00e0 faire \u00e0 la maison, qui seront not\u00e9s.\u003C\/p\u003E\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n                \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EComp\u00e9tences\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003E\u003Cp\u003EComp\u00e9tences acquises \u00e0 l\u0027issue de cet enseignement :\u003C\/p\u003E\n\u003Cul\u003E\n\u003Cli\u003EMod\u00e9lisation, simulation des r\u00e9seaux en r\u00e9gime transitoire, calcul analytique des courants de d\u00e9fauts, r\u00e9glage des protections\u003C\/li\u003E\n\u003C\/ul\u003E\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n        \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003EBibliographie\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003E\u003Cul\u003E\n\u003Cli\u003EPrabha S. Kundur, Om P. Malik, \u0022Power System Stability and Control\u0022, 2nd Edition, 2022 McGraw Hill\u003C\/li\u003E\n\u003Cli\u003EPaul M. Anderson, Charles Henville, Rasheek Rifaat, Brian Johnson, Sakis Meliopoulos, \u0022Power System Protection\u0022, 2nd Edition, 2022 Wiley\u003C\/li\u003E\n\u003C\/ul\u003E\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n        \u003Cdiv class=\u0022field-spacing\u0022\u003E\n      \u003Cdiv class=\u0022field__label h3 dash\u0022\u003ENature de l\u0026#039;\u00e9valuation\u003C\/div\u003E\n                        \u003Cdiv class=\u0022mt-5 text-justify\u0022\u003E\n                                      \u003Cspan\u003EEvaluation Continue non Int\u00e9grale\u003C\/span\u003E\n                      \u003C\/div\u003E\n                  \u003C\/div\u003E\n      \u003C\/div\u003E\n  \u003C\/div\u003E\n\u003C\/div\u003E\n","settings":null}]